Seitenansicht 95
3-28 Ringing in Series II peripherals
297-1001-131 Standard 06.01 October 2000
Procedure 3-1 Dual LCM ringing generator configuration change procedure
At the MAP terminal
1 To access table LCMINV, type
> TABLE LCMINV
and press the Enter key.
2 To position on the tuple for the first LCM, type
> POS HOST 0 0
and press the Enter key.
Example of a MAP display:
For more information about ringing types, refer to chapter "DMS-100 ringing
overview" in this document and the
Customer Data Schema Reference
Manual
.
3 Check the RNGTYPE for the LCM. The previous example shows a
RNGTYPE of frequency selective.
4 To check the RNGTYPE for the other LCM in the LCE frame, type
> POS HOST 0 1
and press the Enter key.
Example of a MAP display:
5 To quit the table, type
> QUIT ALL
and press the Enter key.
6 To access the PM level of the MAP terminal, type
> MAPCI;MTC;PM
and press the Enter key.
Example of a MAP display:
>POS HOST 0 0
HOST 00 0 LCE 4 1 P 29 6X04AA XLCM11BD LTC 0
N 3 256K 256K
LCM Y F REA 20 30 40 50 HLCM (16)(18)(17)(19)$
RNGTYPE is set to frequency selective (F).
>POS HOST 0 1
HOST 00 1 LCE 38 1 P 29 6X04AA XLCM11BD LTC 0
N 8 256K 256K
LCM Y F REA 20 30 40 50 HLCM
(0)(2)(1)(3)$
RNGTYPE is set to frequency selective (F).
SysB ManB OffL CBsy ISTb InSv
PM 0000339
Seitenansicht 95