3-34 Ringing in Series II peripherals
297-1001-131 Standard 06.01 October 2000
26 To exit table LCMINV, type
> QUIT ALL
and press the Enter key.
27 To enter the PM level of the MAP terminal, type
> MAPCI;MTC;PM
and press the Enter key.
28 To post the first LCM and return it to service, type
> POST LCM 0 0
and press the Enter key.
> RTS UNIT 1
and press the Enter key.
29 To post the second LCM and return it to service, type
> POST LCM 0 1
and press the Enter key.
> RTS UNIT 1
and press the Enter key.
30 The following steps complete the procedure and change the ringing
configuration for RG-0 on the same LCM frame or cabinet.
31 Are the units in the LCM aligned to use RG-1?
32 To get an LCM unit to use RG-1, type
> SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the unit number you want to switch to RG-1 (0 or 1)
swrg unit 1
LCM HOST 00 0 Unit 1 SWRG Passed
Perform this step for each LCM unit that needs to use RG-1.
33 To test the ringing generator and LCM unit, type
> TST UNIT 1
and press the Enter key.
34 To busy unit 0 of the second (currently posted) LCM, type
> BSY UNIT 0
and press the Enter key.
If both LCM units Do
are aligned and both use RG-1 Step 33
are not aligned or both do not
use RG-1
Step 32