3-32 Ringing in Series II peripherals
297-1001-131 Standard 06.01 October 2000
17 Reseat RG-1 and restore power.
At the MAP terminal
18 To quit the PM level of the MAP terminal, type
> QUIT ALL
and press the Enter key.
19 To access table LCMINV, type
> TABLE LCMINV
and press the Enter key.
Example of a MAP response:
CI:
TABLE: LCMINV
20 To postion on the tuple for the first LCM, type
> POS HOST 0 0
and press the Enter key.
21 To change the ringing scheme, type
> CHA LCMTYPE
and press the Enter key.
Example of a MAP responce:
ENTER Y TO CONTINUE PROCESSING OR N TO QUIT
Locking lever tabs
Top view
Faceplate
NNoottee: “On” and “Off” settings for DIP
switches can differ among ringing
generators.
SW1SW2SW3SW4
12345678 12345678 12345678 12345678