Ringing in Series II peripherals 3-39
DMS-100 Ringing System
Procedure 3-2 Single LCM ringing generator configuration change procedure
At the MAP terminal
1 To access table LCMINV, type
> TABLE LCMINV
and press the Enter key.
2 To position on the tuple for the LCM, type
> POS RLCM 0 0
and press the Enter key.
Example of a MAP display
For more information about ringing types, refer to the
Customer Data Schema
Reference Manual
and chapter "DMS-100 ringing overview" in this document.
3 Check the RNGTYPE for the LCM. The previous example shows a
RNGTYPE of frequency selective.
4 To quit the table, type
> QUIT ALL
and press the Enter key.
5 To access the PM level of the MAP terminal, type
> MAPCI;MTC;PM
and press the Enter key.
Example of a MAP display:
SysB ManB OffL CBsy IsTb InSv
PM 0000039
6To post the LCM, type
> POST LCM RLCM 0 0
and press the Enter key.
Example of a MAP display
>POS RLCM 0 0
RLCM 00 0 RLCM 4 1 P 29 6X04AA XLCM11BD LTC 0
N 3 256K 256K
LCM Y F REA 20 30 40 50 HLCM
(16)(18)(17)(19)$
RNGTYPE is set to frequency selective (F).