Universal Remote DMS-100 Spezifikationen Seite 64

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 134
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 63
2-6 Ringing in Series I peripherals
297-1001-131 Standard 06.01 October 2000
maintained as long as the signal processor and RGI in each bay operate
properly.
Ringing takeover
If a fault occurred in the signal processor or RGI in either bay, the mate bay
would take over the ringing control function in both bays. If a fault occurred
in the RGI of bay 1, for example, the LM or RLM would report the fault to the
DMS-100 CC. The CC would then send a takeover command to the LM or
RLM controller. In response, the LM or RLM controller would disconnect the
RGI in bay 1 from its ringing generators and switch one RGI link in bay 0 from
its ringing generator to a ringing generator in bay 1 over the crossover
circuitry.
This takeover configuration is illustrated in the following figure. In this
configuration, only one ringing generator in each bay is operational. This
configuration is maintained as long as the fault in the RGI persists.
Seitenansicht 63
1 2 ... 59 60 61 62 63 64 65 66 67 68 69 ... 133 134

Kommentare zu diesen Handbüchern

Keine Kommentare